Table 3-148 lists the mappings between the CE6851-48S6Q-HI and software versions.
Device Series | Sub-series | Device Model | Short Name | Supported Version |
---|---|---|---|---|
CE6800 | CE6850 | CE6851-48S6Q-HI | CE6851HI | V100R005C10 to V200R019C10 NOTE: This model is not supported in V200R005C20. |
The figures in this document are for reference only.
Figure 3-67 CE6851-48S6Q-HI
1 | Power supply slot 1 Applicable power modules: | 2 | Power supply slot 2 Applicable power modules: |
3 | Fan slot 1 Applicable fan modules: | 4 | Fan slot 2 Applicable fan modules: |
5 | Console port | 6 | ETH management port (RJ45) |
7 | Barcode label NOTE: This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch. | 8 | USB port |
9 | Forty-eight 10GE SFP+ Ethernet optical ports Applicable modules and cables:
| 10 | Six 40GE QSFP+ Ethernet optical ports NOTE: A 40GE QSFP+ port can be split into four 10GE ports. Applicable modules and cables: |
11 | Three port-side mounting holes for mounting brackets | 12 | Four power-supply-side mounting holes for mounting brackets |
13 | Ground screw | - | - |
Slot
Power supply slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).
Fan slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6820-48S6CQ-A, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.
All fan modules are hot swappable.
Airflow
The cooling systems of the CloudEngine 8800, 7800, 6800, and 5800 series switches have front-to-back or back-to-front airflow depending on the airflow direction of the power modules and fan modules used. The airflow direction of the power modules and fan modules required on the CloudEngine 8800, 7800, 6800, and 5800 series switches depends on how the switches are installed in cabinets. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If CloudEngine 8800, 7800, 6800, and 5800 series switches are installed with the power supply side facing the front, you are advised to use fan modules and power modules with front-to-back airflow in the switches.
When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.
Figure 3-68 Front-to-back airflow (air flows out from the port side)
Figure 3-69 Back-to-front airflow (air flows in from the port side)
The CE6851-48S6Q-HI does not have a mode switch button and the STAT/SPEED/STACK mode indicator. The downlink service port indicators of the CE6851-48S6Q-HI are 10GE optical port indicators, and other indicators on the CE6851-48S6Q-HI are the same as those on the CE6850-48T4Q-EI. The CE6850-48T4Q-EI. is used as an example here to describe the indicators.
10GE SFP+ Ethernet Optical Port
A 10GE SFP+ Ethernet optical port supports auto-sensing to 1 Gbit/s, and can receive and send services at a rate of 1000 Mbit/s or 10 Gbit/s. Table 3-149 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 3-149 Attributes of a 10GE SFP+ Ethernet optical port
Attribute | Description |
---|---|
Connector type | LC |
Optical attributes | Depending on the module or cable in use |
Standards compliance | IEEE802.3ae |
Working mode | Supported rate: 1000 Mbit/s and 10 Gbit/s auto-sensing Full-duplex |
40GE QSFP+ Ethernet Optical Port
A 40GE QSFP+ Ethernet optical port receives and sends services at the rate of 40 Gbit/s. If a 40GE QSFP+ Ethernet optical port is split into four 10GE ports, it must use 1-to-4 QSFP+ optical modules and optical fibers or 1-to-4 QSFP+ cables. Table 3-150 describes the attributes of a 40GE QSFP+ Ethernet optical port.
Table 3-150 Attributes of a 40GE QSFP+ Ethernet optical port
Attribute | Description |
---|---|
Connector type | LC/MPO |
Optical port attributes | Depending on the module or cable in use |
Standards compliance | IEEE802.3ba |
Working mode | Full-duplex |
Console Port
The console port is connected to a console for onsite configuration. The port must use a console cable. Table 3-151 describes the attributes of the console port.
Table 3-151 Attributes of the console port
Attribute | Description |
---|---|
Connector type | RJ45 |
Standards compliance | RS232 |
Working mode | Duplex Universal Asynchronous Receiver/Transmitter (UART) |
Baud rate | 9600 bit/s to 115200 bit/s Default value: 9600 bit/s |
ETH Management Port (RJ45)
The ETH management port (RJ45) of a switch is connected to the network port of a configuration terminal or network management workstation to set up the onsite or remote configuration environment. The ETH management port (RJ45) uses a Category 5 or higher category cable. Table 3-152 describes the attributes of the ETH management port (RJ45).
Table 3-152 Attributes of the ETH management port (RJ45)
Attribute | Description |
---|---|
Connector type | RJ45 |
Standards compliance | IEEE802.3ab |
Working mode | Supported rate: 10/100/1000 Mbit/s auto-sensing Full-duplex |
Maximum transmission distance | 100 m |
USB Port
A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.
Table 3-153 lists technical specifications of the CE6851-48S6Q-HI switch.
Table 3-153 Technical specifications
Item | Description | |
---|---|---|
Physical specifications |
| |
Environment parameters | Temperature |
|
Relative humidity | 5% RH to 95% RH, noncondensing | |
Altitude | < 5000 m (16404 ft.) | |
Noise (sound pressure, 27°C) |
| |
Power specifications | Power source type | AC/DC |
AC power input |
| |
DC power input |
| |
High-voltage DC power input | Not supported | |
Rated input current |
| |
Chassis power consumption | Maximum power consumption | 245 W |
Typical power consumption | 145 W (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 6 ports, double power modules) | |
Chassis heat dissipation | Maximum heat dissipation | 836 BTU/hr |
Typical heat dissipation | 495 BTU/hr (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 6 ports, double power modules) | |
Surge protection | Power module:
| |
Heat dissipation | Heat dissipation mode | Air cooling |
Airflow | Front-to-back or back-to-front, depending on the fan modules and power modules | |
Reliability and availability | Power module backup | 1+1 backup |
Fan module backup | 1+1 backup not supported NOTE: A CE6800 chassis uses two fan modules, with each fan module containing two fans. The four fans in the chassis work in 3+1 backup mode. | |
Hot swap | Supported by all power modules and fan modules | |
Mean time between failures (MTBF) | 49.08 years | |
Mean time to repair (MTTR) | 1.77 hours | |
Availability | 0.99999587522 | |
Technical specifications | Processor | 1.2 GHz, quad-core |
DRAM Memory | 2 GB | |
NOR Flash | 16 MB | |
NAND Flash | 1 GB | |
Stack | Service port supporting the stack function | 10GE optical ports and 40GE optical ports |
Certification |
|
Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.
Table 3-154 provides the ordering information.
Table 3-154 Ordering information
Part Number | Part Model | Part Description |
---|---|---|
02350JAR | CE6851-HI-F-B0A | CE6851-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Exhaust) |
02350JAS | CE6851-HI-B-B0A | CE6851-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Intake) |
02350JAP | CE6851-48S6Q-HI-F | CE6851-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*FAN Box, Port-side Exhaust, Without Power Module) |
02350JAQ | CE6851-48S6Q-HI-B | CE6851-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*FAN Box, Port-side Intake, Without Power Module) |
02350TJJ | CE6851-48S6Q-HI-X | CE6851-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, Without FAN Box and Power Module) |