Table 3-122 lists the mappings between the CE6850-48T4Q-EI and software versions.
Device Series | Sub-series | Device Model | Short Name | Supported Version |
---|---|---|---|---|
CE6800 | CE6850 | CE6850-48T4Q-EI | CE6850EI | V100R001C00 to V200R019C10 NOTE: This model is not supported in V200R005C20. |
The figures in this document are for reference only.
Figure 3-54 CE6850-48T4Q-EI
1 | Power supply slot 1 Applicable power modules: | 2 | Power supply slot 2 Applicable power modules: |
3 | Fan slot 1 Applicable fan modules: | 4 | Fan slot 2 Applicable fan modules: |
5 | Console port | 6 | ETH management port (RJ45) |
7 | Barcode label NOTE: This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch. | 8 | USB port |
9 | Forty-eight 10GBASE-T Ethernet electrical ports NOTE: When a CE6850-48T4Q-EI switch uses 350 W AC power modules and all its ports are in use, the length of each network cable used on the switch cannot exceed 30 m. | 10 | Four 40GE QSFP+ Ethernet optical ports NOTE: A 40GE QSFP+ port can be split into four 10GE ports. Applicable modules and cables: |
11 | Three port-side mounting holes for mounting brackets | 12 | Four middle mounting holes for mounting brackets |
13 | Four power-supply-side mounting holes for mounting brackets | 14 | Ground screw |
Slot
Power supply slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).
Fan slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6820-48S6CQ-A, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.
All fan modules are hot swappable.
Airflow
The cooling systems of the CloudEngine 8800, 7800, 6800, and 5800 series switches have front-to-back or back-to-front airflow depending on the airflow direction of the power modules and fan modules used. The airflow direction of the power modules and fan modules required on the CloudEngine 8800, 7800, 6800, and 5800 series switches depends on how the switches are installed in cabinets. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If CloudEngine 8800, 7800, 6800, and 5800 series switches are installed with the power supply side facing the front, you are advised to use fan modules and power modules with front-to-back airflow in the switches.
When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.
Figure 3-55 Front-to-back airflow (air flows out from the port side)
Figure 3-56 Back-to-front airflow (air flows in from the port side)
Figure 3-57 Indicators on the CE6850-48T4Q-EI rear panel
Figure 3-58 Indicators on the CE6850-48T4Q-EI front panel
Ports
10GBASE-T Ethernet Electrical Port
A 10GBASE-T Ethernet electrical port receives and sends service traffic at the rate of 100 Mbit/s, 1000 Mbit/s, or 10 Gbit/s. The port can work at the rate of 100 Mbit/s or 1000 Mbit/s through auto-sensing. 10GBASE-T Ethernet electrical ports must use Category 6A shielded Ethernet cables or higher Ethernet cables. Table 3-125 shows the attributes of a 10GBASE-T Ethernet electrical port.
Table 3-125 Attributes of a 10GBASE-T Ethernet electrical port
Attribute | Description |
---|---|
Connector type | RJ45 |
Standards compliance | IEEE802.3an and IEEE802.3az |
Applicable cable | Straight-through cable and crossover cable |
Working mode | Supported rate: 100/1000 Mbit/s and 10 Gbit/s auto-sensing Full-duplex |
Maximum transmission distance | 100 m |
40GE QSFP+ Ethernet Optical Port
A 40GE QSFP+ Ethernet optical port receives and sends services at the rate of 40 Gbit/s. If a 40GE QSFP+ Ethernet optical port is split into four 10GE ports, it must use 1-to-4 QSFP+ optical modules and optical fibers or 1-to-4 QSFP+ cables. Table 3-126 describes the attributes of a 40GE QSFP+ Ethernet optical port.
Table 3-126 Attributes of a 40GE QSFP+ Ethernet optical port
Attribute | Description |
---|---|
Connector type | LC/MPO |
Optical port attributes | Depending on the module or cable in use |
Standards compliance | IEEE802.3ba |
Working mode | Full-duplex |
Console Port
The console port is connected to a console for onsite configuration. The port must use a console cable. Table 3-127 describes the attributes of the console port.
Table 3-127 Attributes of the console port
Attribute | Description |
---|---|
Connector type | RJ45 |
Standards compliance | RS232 |
Working mode | Duplex Universal Asynchronous Receiver/Transmitter (UART) |
Baud rate | 9600 bit/s to 115200 bit/s Default value: 9600 bit/s |
ETH Management Port (RJ45)
The ETH management port (RJ45) of a switch is connected to the network port of a configuration terminal or network management workstation to set up the onsite or remote configuration environment. The ETH management port (RJ45) uses a Category 5 or higher category cable. Table 3-128 describes the attributes of the ETH management port (RJ45).
Table 3-128 Attributes of the ETH management port (RJ45)
Attribute | Description |
---|---|
Connector type | RJ45 |
Standards compliance | IEEE802.3ab |
Working mode | Supported rate: 10/100/1000 Mbit/s auto-sensing Full-duplex |
Maximum transmission distance | 100 m |
USB Port
A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.
Table 3-129 Technical specifications
Item | Description | |
---|---|---|
Physical specifications |
| |
Environment parameters | Temperature |
|
Relative humidity | 5% RH to 95% RH, noncondensing | |
Altitude | < 5000 m (16404 ft.) | |
Noise (sound pressure, 27°C) |
| |
Power specifications | Power source type | AC |
AC power input |
| |
DC power input | Not supported | |
High-voltage DC power input | Not supported | |
Rated input current |
| |
Chassis power consumption | Maximum power consumption | 380 W |
Typical power consumption | 305 W (100% throughput, 3 m Ethernet cables on 48 ports and QSFP+ cables on 4 ports, double power modules) | |
Chassis heat dissipation | Maximum heat dissipation | 1297 BTU/hr |
Typical heat dissipation | 1041 BTU/hr (100% throughput, 3 m Ethernet cables on 48 ports and QSFP+ cables on 4 ports, double power modules) | |
Surge protection | Ethernet electrical ports: 2 kV in common mode AC Power module: 6 kV in common mode and 6 kV in differential mode | |
Heat dissipation | Heat dissipation mode | Air cooling |
Airflow | Front-to-back or back-to-front, depending on the fan modules and power modules | |
Reliability and availability | Power module backup | 1+1 backup |
Fan module backup | Not supported | |
Hot swap | Supported by all power modules and fan modules | |
Mean time between failures (MTBF) | 41.28 years | |
Mean time to repair (MTTR) | 2.0 hours | |
Availability | 0.9999933669 | |
Technical specifications | Processor | 1.5 GHz, quad-core |
DRAM Memory | 2 GB | |
NOR Flash | 8 MB | |
NAND Flash | 1 GB | |
Stack | Service port supporting the stack function | 10GE electrical ports (V100R002 and later versions) and 40GE optical ports |
Certification |
|
Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.
Table 3-130 provides the ordering information.
Table 3-130 Ordering information
Part Number | Part Model | Part Description |
---|---|---|
02359084 | CE6850-EI-B01 | CE6850-48T4Q-EI Switch (2*600W AC Power Module, 2*FAN Box, Port-side Exhaust) |
02350EXT | CE6850-EI-B-B00 | CE6850-48T4Q-EI Switch (2*600W AC Power Module, 2*FAN Box, Port-side Intake) |
02350EXR | CE6850-48T4Q-EI-F | CE6850-48T4Q-EI Switch (48-Port 10G RJ45, 4-Port 40G QSFP+, 2*FAN Box, Port-side Exhaust, Without Power Module) |
02350EXS | CE6850-48T4Q-EI-B | CE6850-48T4Q-EI Switch (48-Port 10G RJ45, 4-Port 40G QSFP+, 2*FAN Box, Port-side Intake, Without Power Module) |
02355265 | CE6850-48T4Q-EI | CE6850-48T4Q-EI Switch (48-Port 10GE RJ45, 4-Port 40GE QSFP+, Without Fan Box and Power Module) |
Low Price Guarantee | ![]() | Quality Assurance | |
100% Money Back Guarantee | Commodity Refund Guarantee | ||
Diversified and Flexible Transportation Services | ![]() | Standard Policy |