CE6810-48S4Q-EI Overview

CE6810-48S4Q-EI

Version Mapping

Table 3-63 lists the mappings between the CE6810-48S4Q-EI and software versions.

Table 3-63 Version mapping

Device Series

Sub-series

Device Model

Short Name

Supported Version

CE6800

CE6810

CE6810-48S4Q-EI

CE6810EI

V100R003C00 to V200R019C10

NOTE:

This model is not supported in V200R005C20.

Appearance and Structure

The figures in this document are for reference only.

Figure 3-27 CE6810-48S4Q-EI

1

Power supply slot 1

Applicable power modules:

2

Power supply slot 2

Applicable power modules:

3

Fan slot 1

Applicable fan modules:

4

Fan slot 2

Applicable fan modules:

5

Console port

6

ETH management port (RJ45)

7

Barcode label

NOTE:

This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch.

8

USB port

9

Forty-eight 10GE SFP+ Ethernet optical ports

Applicable modules and cables:

10

Four 40GE QSFP+ Ethernet optical ports

NOTE:

A 40GE QSFP+ port can be split into four 10GE ports.

Applicable modules and cables:

11

Three port-side mounting holes for mounting brackets

12

Four middle mounting holes for mounting brackets

13

Four power-supply-side mounting holes for mounting brackets

14

Ground screw

Slot

  • Power supply slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).

    • When both power modules are working properly, they equally provide power for a chassis.
    • When one power module fails, the other one provides all power required for a chassis.
    All power modules are hot swappable.
  • Fan slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6820-48S6CQ-A, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.

    All fan modules are hot swappable.

Airflow

The cooling systems of the CloudEngine 8800, 7800, 6800, and 5800 series switches have front-to-back or back-to-front airflow depending on the airflow direction of the power modules and fan modules used. The airflow direction of the power modules and fan modules required on the CloudEngine 8800, 7800, 6800, and 5800 series switches depends on how the switches are installed in cabinets. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If CloudEngine 8800, 7800, 6800, and 5800 series switches are installed with the power supply side facing the front, you are advised to use fan modules and power modules with front-to-back airflow in the switches.

  • Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked  or . Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 3-28 (CE5800 as an example).
  • Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked  or . Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 3-29 (CE5800 as an example).
  • When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.

Figure 3-28 Front-to-back airflow (air flows out from the port side)

Figure 3-29 Back-to-front airflow (air flows in from the port side)

Indicators

The downlink service port indicators of the CE6810-48S4Q-EI are 10GE optical port indicators, and other indicators on these models are the same as those on the CE6850-48T4Q-EI. The CE6850-48T4Q-EI is used as an example here to describe the indicators.

Ports

10GE SFP+ Ethernet Optical Port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1 Gbit/s, and can receive and send services at a rate of 1000 Mbit/s or 10 Gbit/s. Table 3-64 describes the attributes of a 10GE SFP+ Ethernet optical port.

Table 3-64 Attributes of a 10GE SFP+ Ethernet optical port

Attribute

Description

Connector type

LC

Optical attributes

Depending on the module or cable in use

Standards compliance

IEEE802.3ae

Working mode

Supported rate: 1000 Mbit/s and 10 Gbit/s auto-sensing

Full-duplex

40GE QSFP+ Ethernet Optical Port

A 40GE QSFP+ Ethernet optical port receives and sends services at the rate of 40 Gbit/s. If a 40GE QSFP+ Ethernet optical port is split into four 10GE ports, it must use 1-to-4 QSFP+ optical modules and optical fibers or 1-to-4 QSFP+ cables. Table 3-65 describes the attributes of a 40GE QSFP+ Ethernet optical port.

Table 3-65 Attributes of a 40GE QSFP+ Ethernet optical port

Attribute

Description

Connector type

LC/MPO

Optical port attributes

Depending on the module or cable in use

Standards compliance

IEEE802.3ba

Working mode

Full-duplex

Console Port

The console port is connected to a console for onsite configuration. The port must use a console cableTable 3-66 describes the attributes of the console port.

Table 3-66 Attributes of the console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s to 115200 bit/s

Default value: 9600 bit/s

ETH Management Port (RJ45)

The ETH management port (RJ45) of a switch is connected to the network port of a configuration terminal or network management workstation to set up the onsite or remote configuration environment. The ETH management port (RJ45) uses a Category 5 or higher category cable. Table 3-67 describes the attributes of the ETH management port (RJ45).

Table 3-67 Attributes of the ETH management port (RJ45)

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3ab

Working mode

Supported rate: 10/100/1000 Mbit/s auto-sensing

Full-duplex

Maximum transmission distance

100 m

USB Port

A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.

CE6810-48S4Q-EI Specification

Specifications

Table 3-68 Technical specifications

Item

Description

Physical specifications

  • Dimensions (W x D x H): 442.0 mm x 600.0 mm x 43.6 mm (17.4 in. x 23.6 in. x 1.72 in.)
  • Weight (with two power modules and two fan modules, calculated based on the heaviest model if multiple models are supported): 10.4 kg (22.93 lb)

Environment parameters

Temperature

  • Operating temperature: 0°C to 40°C (32°F to 104°F) at altitude of 0-1800 m (0-5906 ft.)

    NOTE:

    When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

  • Storage temperature: -40°C to +70°C (-40°F to +158°F)

Relative humidity

5% RH to 95% RH, noncondensing

Altitude

< 5000 m (16404 ft.)

Noise (sound pressure, 27°C)

  • Back-to-front airflow: < 51 dBA
  • Front-to-back airflow: < 48 dBA

Power specifications

Power source type

AC/DC

AC power input

  • Rated input voltage range: 100 V AC to 240 V AC, 50/60 Hz
  • Maximum input voltage range: 90 V AC to 290 V AC, 47 Hz to 63 Hz

DC power input

  • Rated voltage range: -48 V DC to -60 V DC
  • Maximum voltage range: -38.4 V DC to -72 V DC

High-voltage DC power input

Not supported

Rated input current

  • 350 W DC power (PDC-350WA series): 11 A (-48 V DC to -60 V DC)
  • 600 W AC power (PAC-600WA series): 9 A (100 V AC to 240 V AC)

Chassis power consumption

Maximum power consumption

238 W

Typical power consumption

101 W (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 4 ports, double power modules)

Chassis heat dissipation

Maximum heat dissipation

812BTU/hr

Typical heat dissipation

344 BTU/hr (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 4 ports, double power modules)

Surge protection

Power module:

  • AC: 6 kV in common mode and 6 kV in differential mode
  • DC: 4 kV in common mode and 2 kV in differential mode

Heat dissipation

Heat dissipation mode

Air cooling

Airflow

Front-to-back or back-to-front, depending on the fan modules and power modules

Reliability and availability

Power module backup

1+1 backup

Fan module backup

Not supported

Hot swap

Supported by all power modules and fan modules

Mean time between failures (MTBF)

49.27 years

Mean time to repair (MTTR)

2.0 hours

Availability

0.99999536630

Technical specifications

Processor

1.5 GHz, quad-core

DRAM Memory

2 GB

NOR Flash

16 MB

NAND Flash

1 GB

Stack

Service port supporting the stack function

10GE optical ports and 40GE optical ports

Certification

  • Safety standards compliance
  • EMC standards compliance
  • Environmental standards compliance

Ordering Information

Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.

Table 3-69 provides the ordering information.

Table 3-69 Ordering information

Part Number

Part Model

Part Description

02359247

CE6810-EI-B00

CE6810-48S4Q-EI Switch (2*600W AC Power Module, 2*FAN Box, Port-side Exhaust)

02350EXW

CE6810-EI-B-B0A

CE6810-48S4Q-EI Switch (2*600W AC Power Module, 2*FAN Box, Port-side Intake)

02350EXU

CE6810-48S4Q-EI-F

CE6810-48S4Q-EI Switch (48-Port 10G SFP+, 4-Port 40G QSFP+, 2*FAN Box, Port-side Exhaust, Without Power Module)

02350EXV

CE6810-48S4Q-EI-B

CE6810-48S4Q-EI Switch (48-Port 10G SFP+, 4-Port 40G QSFP+, 2*FAN Box, Port-side Intake, Without Power Module)

02358856

CE6810-48S4Q-EI

CE6810-48S4Q-EI Switch (48-Port 10GE SFP+, 4-Port 40GE QSFP+, Without Fan Box and Power Module)

CE6810-48S4Q-EI Warranty

Low Price Guarantee
Customers can get high quality products at wholesale prices

Quality Assurance
All products sold are original genuine goods, new packaging unopened

100% Money Back Guarantee
If your returns meet our relevent standards,you can contact our customer service team to exchange or return any product that you bought from us

Commodity Refund Guarantee
For equipment purchased from us, please contact our customer service team for return and replacement services

Diversified and Flexible Transportation Services
Cargo carriers include Fedex, DHL, UPS, Aramex, TNT, EMS

Standard Policy
1 Year