Table 4-28 Basic information about the CE6855-48XS8CQ
Item | Details |
---|---|
Description | CE6855-48XS8CQ switch (48*10GE SFP+, 8*100GE QSFP28, Without Fan and Power Modules) |
Part Number | 02355KTJ |
Model | CE6855-48XS8CQ |
First supported version | V300R023C00 |
Other part numbers | 02355KTK (CE6855-48XS8CQ switch (48*10GE SFP+, 8*100GE QSFP28, 2*AC Power Modules, 3*Fans, Port-side Intake)) 02355KTL (CE6855-48XS8CQ switch (48*10GE SFP+, 8*100GE QSFP28, 2*AC Power Modules, 3*Fans, Port-side Exhaust)) |
Short Name | CE6855-48XS8CQ |
Figure 4-34 Appearance of the CE6855-48XS8CQ
Table 4-32 Technical specifications of the CE6855-48XS8CQ
Item | Specification |
---|---|
Dimensions with packaging (H x W x D) [mm (in.)] | 185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] |
|
Weight without packaging [kg (lb)] | 6.36 kg (14.02 lb) (excluding optical modules, power modules, and fan modules) |
Weight without packaging (full configuration) [kg (lb)] | 8.35 kg (18.41 lb) (including AC power modules and fan modules, excluding optical modules, calculated based on the heaviest model if multiple models are supported) |
Weight with packaging [kg (lb)] | 10.63 kg (23.43 lb) |
Weight with packaging (full configuration) [kg (lb)] | 12.62 kg (27.82 lb) |
Chassis height [U] | 1 U |
Installation Type | Cabinet installation |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
CPU | 4-core, 1.4 GHz |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB |
SSD Flash | 4GB SSD |
USB | It can be used for log backup and USB-based deployment. This function is reserved. |
Power supply mode |
|
Console port | RJ45 |
Downlink Service interface | 48*10GE SFP+ |
Uplink Service interface | 8 x 100GE QSFP28 |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Typical power consumption [W] | 138 W (100% traffic load, copper cables on 24 x 10GE + 4 x 100GE ports, normal temperature, dual AC power modules) 156 W (100% traffic load, short-distance optical modules on 24 x 10GE + 4 x 100GE ports, normal temperature, dual AC power modules) |
Typical heat dissipation [BTU/hour] |
|
Static power consumption [W] | 124 W |
Static heat dissipation [BTU/hour] | 423 BTU/hour |
Maximum power consumption [W] | 187 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 298 W (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) |
Maximum heat dissipation [BTU/hour] |
|
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] |
|
Rated output power [W] |
|
Certification |
|
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fan modules | 3 |
Redundant fans | The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction. |
Availability | 0.9999948505 |
MTBF [year] | 44.34 years |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Front-to-back airflow: 50.1 dB(A) on average; maximum: 55.9 dB(A) Back-to-front airflow: 48.4 dB(A) on average; maximum: 56.1 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Front-to-back airflow: 66.4 dB(A) on average; maximum: 73.2 dB(A) Back-to-front airflow: 67.3 dB(A) on average; maximum: 72.5 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.) NOTE: When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
Low Price Guarantee | ![]() | Quality Assurance | |
100% Money Back Guarantee | Commodity Refund Guarantee | ||
Diversified and Flexible Transportation Services | ![]() | Standard Policy |